Sailing Catalpaβίντεο

All we needed was this little piece Episode 459

31 Αυγούστου 2025 · 17 λεπτά · 9K προβολές · El Salvador

Τι καλύπτει αυτό το βίντεο

A 9kVA Paguro generator on the 10-year liveaboard vessel Catalpa failed to produce power due to a faulty current transformer.9:09 The owner diagnosed the issue by tracing the wiring and identifying a broken terminal on the transformer, which acts as a safety interlock for the generator's output.9:49 He replaced the failed component with a 50-amp, 50-milliamp Blue Sea Systems current transformer and a new 180-ohm resistor, soldering the connections and securing the assembly with zip ties.13:18 Testing confirmed the repair restored power, enabling the crew to resume water production and battery charging.15:10 The owner also installed an hour meter on the boat's 15-horsepower Mercury four-stroke EFI outboard and modified the cockpit table to improve deck space.8:29 Future maintenance plans include replacing a broken exhaust temperature sensor to prevent potential overheating of the plastic exhaust muffler.15:52 Troubleshooting electrical components requires basic soldering skills, a multimeter, and access to wiring diagrams.

Παρακολουθήστε στο YouTube

Περισσότερα από το Sailing Catalpa

they weren't expecting thisΣεπ 2026one of the most remote islands on the planetΣεπ 202629 days sailing Panama to French Polynesia the whole passageΑυγ 2026what did we learn from a month at seaΑυγ 2026

Από Sailing Catalpa — δείτε το σκάφος του καναλιού, το πλήρωμα και κάθε αναλυμένο βίντεο.

The Sailing Directory Newsletter

Ένα email με τις καλύτερες ανακαλύψεις του στόλου — τις στιγμές, τα σκάφη και τις ιστορίες που αξίζουν τον χρόνο παρακολούθησής σας. Εισάγετε τη διεύθυνσή σας για να λάβετε το δικό σας αντίγραφο.

Αναφορά προβλήματος