VOILIER ODINβίντεο

220V ELECTRICAL PANEL AND 12V BILGE PUMPS

2 Ιουλίου 2023 · 31 λεπτά · 6K προβολές

Τι καλύπτει αυτό το βίντεο

Installing a 220V electrical distribution system and 12V bilge pumps requires careful cable routing through a steel-hulled vessel. The project involves pulling 6mm² wire for bilge pumps and toilet systems, alongside 220V cabling for multiple cabin outlets.1:24 To manage the wiring, the installer uses conduits behind bulkheads and secures cables with clips to prevent interference within storage areas.12:39 A waterproof 220V distribution box houses a 30mA residual current device and four circuit breakers, designated for outlets, a battery charger, and a refrigerator.20:47 During navigation, the charger and outlets remain disconnected to prevent the 12V-to-220V inverter from creating a power loop by feeding the charger.20:55 The installer emphasizes the importance of labeling cables clearly to distinguish between 12V and 220V lines, noting that color coding—blue for neutral and black for phase—differs from standard 12V red-and-black conventions.11:07 Proper insulation of the steel hull is identified as a critical step to manage cabin temperatures.28:30

Παρακολουθήστε στο YouTube

Σκάφη σε αυτό το βίντεο

Etap 38iΤο σκάφος τους

Περισσότερα από το VOILIER ODIN

SAILING ATYPIC AT THE PAVOIS IN LA ROCHELLEΟκτ 2026Sailing under asymmetric spinnaker with a Sun OdysseyΑυγ 2026TOP NAVIGATION - WORTH REPEATING WITHOUT HESITATIONΑυγ 2026WHY I'M MOVING BACK TO FRANCEΙουλ 2026

Από VOILIER ODIN — δείτε το σκάφος του καναλιού, το πλήρωμα και κάθε αναλυμένο βίντεο.

The Sailing Directory Newsletter

Ένα email με τις καλύτερες ανακαλύψεις του στόλου — τις στιγμές, τα σκάφη και τις ιστορίες που αξίζουν τον χρόνο παρακολούθησής σας. Εισάγετε τη διεύθυνσή σας για να λάβετε το δικό σας αντίγραφο.

Αναφορά προβλήματος