A Hans Christensen sailboat owner reports measuring DC voltage at the distribution panel despite disconnecting the battery leads and disabling the inverter while connected to shore power.0:33 This condition occurs when a battery charger is incorrectly wired to the switched side of the DC distribution system rather than the unswitched side.2:23 When connected to the switched side, the battery charger acts as a power supply, energizing the DC panel even when the main battery switch is off.2:23 This improper installation creates a circuit where shore power feeds the charger, which in turn powers the DC distribution panel directly.2:39 To ensure the DC panel de-energizes when the battery switch is turned off, all charging sources—including battery chargers, solar controllers, and fuel cells—must connect exclusively to the unswitched distribution side.3:27 Proper separation of switched and unswitched distribution prevents this unintended energization and ensures predictable electrical system behavior.3:38

Se på YouTube

Mer fra Pacific Yacht Systems

There Is NO MORE ROOM For Additional Batteries, What Do You Do? PYS Tech Talksep. 2026DIY vs Professional Boat Electronics, What to Look for When Buying Used - PYS Tech Talkaug. 2026When Battery Charging Through An Inverter Might Make Sense - PYS Tech Talkaug. 2026Upgrading Your Alternator? These Are OUR Top Tips - PYS Tech Talkaug. 2026

Fra Pacific Yacht Systems – se kanalens båt, mannskap og alle analyserte videoer.

The Sailing Directory Newsletter

Én e-post med flåtens beste funn – øyeblikkene, båtene og historiene som er verdt din seertid. Skriv inn din egen adresse for å få din egen kopi.

Rapporter et problem