Mer
SprÄk
Visningsmodus
12. april 2026 · 22 min · 190K visninger · Rebak Island, Langkawi
White catamaran powers through marina, twin hulls churning green water.
Hva denne videoen dekker
The crew of a Lagoon 450 addresses severe diesel bug contamination and tank corrosion by installing custom inspection hatches and a fuel transfer system. After discovering heavy sludge and water in the port-side aluminum fuel tank, the owner cuts an inspection hatch to clean the interior, revealing significant pitting on the tank floor.â¶ 0:48 A similar inspection of the starboard tank reveals less severe corrosion but confirms the presence of water and microbial growth.â¶ 9:51 To manage the fuel, the owner designs a transfer system using 50 feet of fuel hose, a series of valves, and a pump to polish fuel through existing 10-micron Racor filters.â¶ 2:43 A recirculation line allows for flow rate control to prevent overloading the filters.â¶ 3:20 The owner seals the new custom aluminum inspection lids using 38 bolts per tank, Loctite 577 fuel-grade sealant, and fiber washers.â¶ 13:57 The project highlights the risks of factory-sealed tanks that lack bottom-draw pickups or inspection access, which prevent the removal of water and acidic sludge.
BÄter i denne videoen
Mer fra Sailing Parlay Revival