Qué cubre este vídeo

Jan Attenstedt and Nigel Calder discuss the feasibility of paralleling two 250-amp relays to manage the high current draw of a 6-kilowatt, 24-volt bow thruster.0:41 The owner reports repeated relay failure, likely caused by electrical arcing that melts the contact points shut during operation.0:02 Calder confirms that paralleling two relays effectively reduces the current load per unit and mitigates the risk of contact welding.1:33 He notes that high-current DC circuits inherently produce arcs during make-and-break cycles, which degrades the relay points over time.1:48 Calder emphasizes that if an emergency battery isolation switch is used to break a high-amperage circuit during a short or a stuck-relay event, the switch sustains internal damage and requires immediate replacement.2:47 These switches are rated for carrying high loads but not for interrupting them under load.3:21 Paralleling relays provides a viable solution for systems experiencing premature contact failure due to high current demands.1:07

Ver en YouTube

Más de BoatHowTo

Rewiring an old boat if everything works as should? 😟💰 | Ask The Expert with NIGEL CALDERoct 2026Grounding on Aluminium Yachts 🔧 | Ask The Expert with NIGEL CALDERsept 2026Boat ELECTRIC PROPULSION with only LEAD ACID Batteries ?? | Ask The Expert with NIGEL CALDERsept 2026MaxProp: More Pitch in Reverse than in Forward? 🤔 | Ask The Expert with NIGEL CALDERsept 2026

De BoatHowTo — mira el barco del canal, la tripulación y cada vídeo analizado.

The Sailing Directory Newsletter

Un correo electrónico con los mejores hallazgos de la flota: los momentos, barcos e historias que merecen tu tiempo de visionado. Introduce tu dirección para recibir tu propia copia.

Informar de un problema