Finding GROUND FAULTS - When NOT to trust your marine electrician | Ask The Expert with NIGEL CALDER

7 mars 2024 · 3 min · 4K vues

Ce que couvre cette vidéo

A 2003 American-built boat exhibits a six-to-seven-volt neutral-to-ground voltage drop and a 15% line voltage loss under a 15-amp load.0:27 These symptoms suggest a high-resistance connection rather than a systemic wiring failure. Nigel Calder advises against dismantling the boat’s electrical system, noting that such invasive measures often obscure the root cause.1:40 Instead, systematic testing with a multimeter can isolate the fault location.1:46 The most likely culprit in a 120-volt split-phase shore power system is a poor connection within the shore power circuit, such as a loose neutral terminal.2:43 Troubleshooting should focus on identifying these high-resistance points through voltage drop testing at various connection points before considering major rewiring.2:14 Proper diagnostic testing typically reveals the fault without requiring extensive demolition of the vessel's interior.2:05

Regarder sur YouTube

Plus de vidéos de BoatHowTo

Grounding on Aluminium Yachts 🔧 | Ask The Expert with NIGEL CALDERsept. 2026Boat ELECTRIC PROPULSION with only LEAD ACID Batteries ?? | Ask The Expert with NIGEL CALDERsept. 2026MaxProp: More Pitch in Reverse than in Forward? 🤔 | Ask The Expert with NIGEL CALDERsept. 2026Common Ground Point with Isolated Saildrives | Ask The Expert with NIGEL CALDERsept. 2026

De BoatHowTo — voir le bateau, l'équipage et chaque vidéo analysée de la chaîne.

The Sailing Directory Newsletter

Un e-mail avec les meilleures trouvailles de la flotte — les moments, les bateaux et les histoires qui valent la peine d'être regardés. Entrez votre adresse pour recevoir votre propre exemplaire.

Signaler un problème