sailing.directory
KanalerBåterSpørOm
🇳🇴
🇺🇸English🇬🇧English (UK)🇲🇽Español (México)🇪🇸Español (España)🇫🇷Français🇮🇹Italiano🇵🇹Português (Portugal)🇧🇷Português (Brasil)🇬🇷Ελληνικά🇳🇴Norsk
Logg inn
sailing.directory

En indeks over seilkanaler på YouTube — søkbar etter tema, navigerbar etter interesse. Nye kanaler og båter, indeksert ukentlig. Ingen støy.

Utforsk

KanalerBåterSøkOmForeslå en kanal

Skapere og juss

Støtt ossFor skaperePersonvernVilkårDMCA

Ikke navigasjonsråd · © 2026

HjemKanalerBåter

Mer

SøkSpørOmStøtt ossFor skapereLogg inn

Språk

🇺🇸English🇬🇧English (UK)🇲🇽Español (México)🇪🇸Español (España)🇫🇷Français🇮🇹Italiano🇵🇹Português (Portugal)🇧🇷Português (Brasil)🇬🇷Ελληνικά🇳🇴Norsk

Visningsmodus

sailing.directory
KanalerBåterSpørOm
🇳🇴
🇺🇸English🇬🇧English (UK)🇲🇽Español (México)🇪🇸Español (España)🇫🇷Français🇮🇹Italiano🇵🇹Português (Portugal)🇧🇷Português (Brasil)🇬🇷Ελληνικά🇳🇴Norsk
Logg inn

BoatHowTo · video

ONE SWITCH for TWO PUMPS?? (Pontoon Boat Setup) | Ask The Expert with NIGEL CALDER

11. juli 2026 · 2 min · 742 visninger

Se på YouTube

Hva denne videoen dekker

A pontoon boat with one bilge pump in each pontoon uses a single manual switch to operate both pumps simultaneously.▶ 0:23 Nigel Calder explains the builder likely wired them this way to save money on a second switch.▶ 0:00 The arrangement is acceptable because centrifugal bilge pumps can run dry without burning out, so running both when only one pontoon has water causes no damage.▶ 0:49 The manual switch is adequate for basic operation but inadequate for testing: it confirms the pumps spin but cannot verify the float switches.▶ 0:49 Each float switch has wiring routed through its hinge, and water intrusion there causes stray current corrosion that destroys the positive terminal inside the switch, disabling automatic operation.▶ 1:10 Calder notes boats have sunk because owners assumed the manual test confirmed full system function when the float switches had already failed.▶ 1:55 Proper testing requires physically lifting each float switch, or flooding the bilge if the switch is inaccessible, to confirm automatic activation.▶ 1:50 Separate switches per pump are not required, but float switch inspection is.

Mer fra BoatHowTo

OIL LEAKS at the Crankshaft... | Ask The Expert with NIGEL CALDERjuli 20261-2-both switch - Cost effective charging system on small boats? 🤔 Ask The Expert with NIGEL CALDERjuni 202648V or 24V - What makes more sense on a Boat? | Ask The Expert with NIGEL CALDERjuni 2026How to identify GROUND LEAKS on your BOAT! | Ask The Expert with NIGEL CALDERjuni 2026

Fra BoatHowTo – se kanalens båt, mannskap og alle analyserte videoer.

Rapporter et problem
HjemKanalerBåter

Mer

SøkSpørOmStøtt ossFor skapereLogg inn

Språk

🇺🇸English🇬🇧English (UK)🇲🇽Español (México)🇪🇸Español (España)🇫🇷Français🇮🇹Italiano🇵🇹Português (Portugal)🇧🇷Português (Brasil)🇬🇷Ελληνικά🇳🇴Norsk

Visningsmodus

sailing.directory

En indeks over seilkanaler på YouTube — søkbar etter tema, navigerbar etter interesse. Nye kanaler og båter, indeksert ukentlig. Ingen støy.

Utforsk

KanalerBåterSøkOmForeslå en kanal

Skapere og juss

Støtt ossFor skaperePersonvernVilkårDMCA

Ikke navigasjonsråd · © 2026