Man stands beneath hull as electricity arcs from grounding connection.
Hva denne videoen dekker
A small electrical tingle felt when touching a boat's propeller signals a potentially lethal AC fault current finding its way from the boat's electrical system to the prop.â¶ 0:47 Nigel Calder explains that anyone touching the prop â a diver, a swimmer nearby, or a person on the hard â can become the fault path to ground, risking ventricular fibrillation and electrocution that can look like drowning.â¶ 2:46 Two compounding failures are likely: an internal AC wiring fault on the boat, and a missing or failed ELCI or RCD on the shore power connection.â¶ 1:43 A functioning ELCI or RCD should trip at fault-current levels strong enough to produce a tingle; its absence means the protection layer is gone.â¶ 1:54 Reverse polarity at the shore power plug is also raised as a possible contributor.â¶ 2:04 Calder notes that European dockside outlets routinely carry RCDs, making this scenario more likely on a US boat, particularly in fresh water where the risk to swimmers is highest.â¶ 2:42 Both the internal fault and the shore power protection must be fixed; Calder recommends a professional marine electrician rather than a DIY trace.â¶ 3:11
Mer fra BoatHowTo
Fra BoatHowTo â se kanalens bĂ„t, mannskap og alle analyserte videoer.