Sailing Sweet Rucavideo
Tech Talk - 12v Refrigeration - Isotherm vs Sea Frost - Off the Grid
2. september 2021 · 10 min · 19K visninger
Hva denne videoen dekker
The crew of Sweet Ruca replaces an aging Seafrost BD-50 refrigeration unit with a newer Isotherm system to address persistent refrigerant leaks and high power consumption.1:50 The original Seafrost unit, which draws approximately 5 amps, suffered from repeated leaks at the Presta valves and swage fittings, allowing air and moisture to contaminate the system.1:05 The replacement Isotherm unit features a more compact design and a digital controller, which the crew expects will improve efficiency and reduce average power draw to roughly 2.5 amps.3:32 Key physical differences include the Isotherm’s smaller condensing unit, optimized airflow path, and the inclusion of a water vapor filter to protect the capillary system.4:56 The Isotherm ITC controller provides digital temperature monitoring and adjustable power settings, allowing for one-degree temperature increments.9:48 The crew attributes the previous system's failure to aging components and moisture buildup rather than an inherent flaw in the BD-50 compressor, which both units share.1:07
Mer fra Sailing Sweet Ruca
Fra Sailing Sweet Ruca – se kanalens båt, mannskap og alle analyserte videoer.
The Sailing Directory Newsletter
Én e-post med flåtens beste funn – øyeblikkene, båtene og historiene som er verdt din seertid. Skriv inn din egen adresse for å få din egen kopi.