BoatHowTovídeo
CORROSION on a boat: Stray Current or Galvanic? | Ask The Expert with NIGEL CALDER
16 de maio de 2024 · 6 min · 22K visualizações
O que este vídeo aborda
Rapid depletion of zinc anodes at the dock typically indicates galvanic corrosion rather than stray current.2:04 Galvanic corrosion occurs when a boat lacks a galvanic isolator or isolation transformer, causing the vessel’s zincs to protect other metal objects or boats connected to the same shore power ground.2:04 Stray current corrosion, by contrast, involves a positive DC conductor fault that bypasses the zinc and causes rapid metal loss on the positive side of the circuit.0:53 Standard multimeters cannot accurately diagnose these issues while the boat is in the water.2:27 Accurate testing requires a silver-silver chloride half-cell lowered into the water to measure millivoltage across the bonding system.2:39 To prevent galvanic corrosion, install a galvanic isolator or an isolation transformer.4:50 Alternatively, disconnect shore power when not actively charging batteries, relying on solar power or other independent sources to maintain the battery bank.4:58
Mais de BoatHowTo
De BoatHowTo — veja o barco, a tripulação e todos os vídeos analisados do canal.
The Sailing Directory Newsletter
Um email com os melhores achados da frota — os momentos, barcos e histórias que valem o seu tempo de visualização. Insira o seu endereço para receber a sua cópia.