He's TORN my Kitchen APART! - Isotherm CRUISE 130 Elegance Installation
7 de julio de 2020 · 19 min · 45K visitas
Qué cubre este vídeo
Installing an Isotherm Cruise 130 Elegance fridge into the Millennial Falcon requires removing the existing top-loading fridge box, including the stainless steel lining and waterlogged foam insulation.2:56 The installation process involves constructing a new base floor to support the unit and ensure proper ventilation.8:14 To maximize compressor efficiency, the installation incorporates a floating floor design that allows air to circulate under the fridge, up the back, and out through two 12-volt computer fans mounted at the top.14:19 Proper electrical installation is critical to minimize voltage drop; using high-gauge wire directly from the breaker board ensures the fridge receives full battery voltage, preventing premature low-voltage cutoffs.12:33 After three days of labor, the unit fits into the modified cabinetry, providing 130 liters of storage.16:54 The fridge draws approximately 4.5 amps, performing efficiently despite high ambient temperatures.17:57 Proper ventilation and minimizing voltage drop are the primary factors for maintaining compressor efficiency in marine refrigeration installations.
Barcos en este vídeo
Más de Sailing Millennial Falcon
De Sailing Millennial Falcon — mira el barco del canal, la tripulación y cada vídeo analizado.
The Sailing Directory Newsletter