Van Electrical Nightmares? Fixing Broken Systems at VanFest!
19 November 2023 · 30 min · 10K views · Hurricane, Utah
What this video covers
Nate from EXPLORIST life performs electrical system diagnostics on three camper vans at VanFest in Hurricane, Utah.Watch For a 24-volt system with 800 amp-hours of battery, he corrects incorrect Victron SmartShunt settings that caused premature 100% state-of-charge readings; he adjusts the charged voltage to 28.2 volts and changes the battery state-of-charge reset to clear to ensure accurate synchronization.0:56 On a second van, he investigates reports of melting plastic and identifies undersized 10-gauge wiring and loose lugs on a 4,000-watt inverter.5:52 He recommends replacing existing wiring with 2-0 and 4-0 gauge cable and installing fuses between the battery bank, bus bars, and positive terminals to prevent fire hazards.11:18 Finally, he troubleshoots a 120-volt AC distribution panel in a 30-year-old van where the air conditioner functions but outlets remain dead.14:45 He isolates the issue to a potentially faulty tandem breaker or loose wiring behind the distribution panel.16:36 Proper wire sizing and fusing are essential for high-wattage inverter safety.
More from EXPLORIST life Mobile Marine & Off-Grid Electrical
From EXPLORIST life Mobile Marine & Off-Grid Electrical — see the channel’s boat, crew, and every analysed video.
The Sailing Directory Newsletter
One email with the fleet's best finds — the moments, boats, and stories worth your watch time. Enter your own address to get your own copy.